Desk Occupancy Sensor
Desk Occupancy Sensor
PIR008

    Identifying the utilisation of a workplace position through movement and thermal measurement.

     

    This battery powered, wireless occupancy sensor identifies the utilisation of a workplace position through movement and thermal measurement.

    In an office environment, this sensor would be placed under the desk, at a team table, reception desk etc. Any location occupied by a person. It is the combined measurement of all these positions that provide valuable insights into how your space is used.

    The sensor is continually monitoring the occupation so the data provides real-time fact-based proof of occupancy over long periods of time supporting changes within the workplace by identifying those occupants with high levels of mobility.

Please contact us for pricing and Trade accounts or request a quote using the 'add to quote' button below. You can create a list of items and send a quote request direct to us. 

 To view your quote list please click on the 'view quote' button on the edge of this page. When you are ready please fill in your details and click on submit. We will then get back to you with a quote.

    View Quote

For the most up-to-date information on this product please download the Product Brochure above. 


  • OVERVIEW
  • Detail
  • TECHNICAL

Features, Benefits & Functions

  • Easy to implement and set up
  • Real-time measurement
  • Data 24/7 – 365 days
  • High level of accuracy
  • Low maintenance
  • Family of products
  • Monitors the profile usage
  • Foundation data
  • Battery powered min 3 years

This battery powered, wireless occupancy sensor identifies the utilisation of a workplace position through movement and thermal measurement. 

 

In an office environment, this sensor would be placed under the desk, at a team table, reception desk etc. Any location occupied by a person. It is the combined measurement of all these positions that provide valuable insights into how your space is used. 

 

The sensor is continually monitoring the occupation so the data provides real-time fact-based proof of occupancy over long periods of time supporting changes within the workplace by identifying those occupants with high levels of mobility.

Technical

Environmental 
Operating Temperature- 0°C to +50°C
Relative Humidity5% to 95%
 (non-condensing)
Power Requirements 
Supply Voltage3xAAA 4.8V to 2.5V
Operating Current (Per Transmit)25mA
Operating Current (Per Receive)none
Sleep Current<10uA
  
Dimensions 
Width80mm
Height22mm
Length80mm
Weight (without ext. Batteries)64 grams
  
RF Operation 
Operating Frequency Band315,433,868,922Mhz
AntennaInternal Wire Antenna
  
RF Performance 
Indoor50 metres
Urban Range (line-of-sight)100 metres+
Outdoor RF line-of-sight Range100 metres
Transmit Power Output10dBm RF
Data Rate250kbps
Serial Interface Data Rate1.2kbps to 500kbps
Receiver Sensitivity (868Mhz)107dBm to 129dBm
  
Networking and Security 
Supported Network TopologiesiLan proprietary
Number of Channels (868Mhz)16 Channels
Certifications+ Time Slot Allocation
Europe (CE)ETSI
USA (FCC)FCC